Myron L

PT1

Conductivity, TDS, Salinity Pen

 
PT1

High Performance Features

Accuracy of ±1% of READING

±.2% at Calibration Point

Reliable Repeatable Results

KCl, NaCl and 442™

Natural Water Modes

Automatic Temperature

Compensation

Autoranging

Durable, Fully Potted

Circuitry

Waterproof

PT1 Comes with:

PT1 Pocket Tester Pen -

battery installed

Scoop

Pocket Clip

Holster

Lanyard

Operating Instructions

   

   

 Pump Containment Shelf

 
Containment shelf   

The Pump Containment Shelf (part # 42411)is designed to safely and securely mount your metering pumps on a wall or level surface and contain any potential spills caused by pump or tubing leaks. The Pump Containment Shelf has a 1/4” FPT drain connection on the base that can be connected to a drum or other container to automatically catch any potential leaks that may occur. The pump base is elevated and removable for the easy installation and servicing or your pumps. The cover protects your equipment from the elements and tampering by unauthorized personnel. The view window allows visual inspection of the enclosures interior while the lid is secured. Designed for up to 2 standard Pulsatron or Chem-Tech metering pumps.

   

Myron L

bluDock logo

Transfer data stored in Ultrameter II™, PoolPro™ and Digital Dialysate Meters™handheld instruments to U2CI application via Bluetooth*** wireless technology Reduce Data logging errors Reduce Data logging time Share saved water sample data Lose the clipboard and still easily comply with recordkeeping requirements Product highlights

 

Transfer data wirelessly with accuracy, reliability and simplicity.

• Easy to install software from CD or website: http://myronl.com/main/U2CI_Application_DL.htm

The U2CI™ application will operate on Windows XP, Vista and 7*; and Macintosh OSX**. If you are running an older operating system, contact the Myron L Company.

Automatic organization of data (record number, type of measurement, value and instrument measurement, solution type, temperature, date and time stamp)

Exports to Office software (Word*, Excel*, Works*, etc.) using universal formatting (.csv) files.

Associate all data from a particular instrument by assigning a instrument name.

Control instrument time and date.

Clear instrument memory.

Dongle accessory included for Mac or PC platforms that do not have built-in Bluetooth*** wireless communication capabilities.

 

Myron L Dialysate Meter


D6
Definitive Dialysate Testing
The D-6 is specifically designed to test both acetate and bicarbonate dialysate quality. Measure Conductivity, pH and Temperature to ensure proper mixing during dialysate preparation and as a final check of dialysate quality before hemodialysis treatment. There are no strips or reagents that expire or subjective interpretation of results. Internal sensors require the user to place the sample in the instrument, preventing contamination of dialysate by the measurement device.
Comprehensive Water Quality Analysis for Hemodialysis
The D-6 also measures parameters critical in water quality monitoring and control at every stage of hemodialysis water treatment. Test Conductivity, Resistivity, TDS, pH, ORP, Free Chlorine and Temperature of feed and product water in unit processes.
 Use measurements as independent checks against automatic systems of control and to check residual levels of sanitizers in water treatment and hemodialysis systems after system maintenance.
 Powerful, portable D-6 features extreme accuracy in widely varying ranges, easy one-touch measurements and keypad calibration.
 Bluetooth® communication available with bluDock™ option for easy record-keeping.

 Stenners Injection system And Flow Indicator  

pro inj sys

 Proportional Injection System

The Proportional Injection System delivers precise dosing proportional to the system's flow rate based on water volume. The system is perfectly suited for constant pressure (variable speed) well pumps, poultry and livestock houses, irrigation, systems with demand based backup wells and any application with varying flow rates

The primary components are the Pump Control Module, Classic Series Fixed Output Pump and a dry contact pulsing Water Meter. The Pump Control Module is a time adjusted controller that powers the pump. A pulsing water meter sends a signal to the PCM which actuates the pump to deliver the desired dose based on water volume. The PCM has a locking dial to assure the accuracy of the dosage.

flow ind.

Flow Indicator

The flow indicator is a convenient visual reference (especially with black suction/discharge tubing) to confirm solution is pumping into the system. It also provides an indication of common issues such as plugged injection point, ruptured or worn tube or empty solution tank and assists with impeding backflow.

 